| 详细介绍 |
|
ScopeLogic - complete data acquisition system - consists of Digital Oscilloscope and Logic Analyzer. This small instrument is making the accurate analysis of complex analog-digital signals possible - thanks to simultaneous sampling finding relationship between these signals is easy. The user is able to simultaneous use 16 digital channels and 2 analog channels with standard scope probes.
Maximum frequency of sampling while using all channels is 100MHz. Higher sampling frequenciy are available after reducing the number of used channels.
Trigger options are available both for digital and analog parts. In the analog part it is typical oscilloscope trigger with variable voltage level, in the digital part the triger can occur on the slope or specific combination of levels of digital signals.
Additionally, the logic analyzer is offering the possibility of registration of signals with regulated time delay, change threshold level, skipping defined quantity of edges after trigger, counting the quantity of edges on any channel after the trigger occurs. Basic version of the instrument is equipped with 128K data buffer, optionally it can be enlarged up to 512KB.
Complete data acquisition system - composition of Digital Oscilloscope and Logic Analyzer
Maximum sampling rate:
200MHz - 8 digital channels, 1 analog
100MHz - 16 digital channels, 2 analog
ADC resolution: 8 bits
Analog bandwidth: 20MHz
Input voltage range: 25V (probe 1:1)
128KB data buffer (optionally 512KB)
Spectral analysis (FFT)
Easy to use software
|
| 功能描述 |
|
| Sampling rates |
200MHz*, 100MHz, 50MHz, 20MHz, 10MHz, 5MHz, 2MHz, 1MHz, 500kHz, 200kHz, 100kHz, 50kHz, 20kHz, 10kHz, 5kHz, 2kHz, 1kHz, 500Hz, 200Hz |
| Analog inputs |
2 channels analog gains: 5V/div, 2V/div, 1V/div, 500mV/div, 200mV/div, 100mV/div, 50mV/div, 20mV/div (5 divsprobe 1:1 ) maximum input voltage: 25V (probe 1:1) ADC resolution: 8-bits analog bandwidth: 20MHz coupling: AC, DC input impedance: 1MOhm, 15pF |
| Digital inputs |
16 channels maximum input voltage: from -50V to 50V |
| Data buffer |
Variable: 256, 512, 1024, 2048, 4096, 8192, 16384, 32768, 65536, 131072, 262144*, 524288* samples |
| Trigger (analog) |
Level triggering (rising or falling edge) with noise reduction feature, |
| Trigger (digital) |
Edge - rising, falling, any Edge, skip N - trigger after Nth edge (rising or falling) Pattern - any combination of "1", "0", "don't care" state Edge and (or) Pattern - combinations of edge and pattern triggers Trigger may be also forced by user. |
| Trigger level |
Variable level for digital signals: 0.8V, 1.0V, 1.2V, 1.5V, 1.8V, 2.2V |
| Capture delay |
Depending on sampling rate: for 200MHz max. 500ms, for 100Mhz - 1s, etc. |
| Pre- and Post Trigger buffers |
Variable size of Pre- and Post Trigger buffers |
| External clock input |
Synchronized capturing with external clock. Input: digital channel 16, max. frequency: 10MHz. |
| Power supply |
External, 5V/1A |
| Dimensions |
Width: 110mm, length: 130mm, height: 42mm |
| Software |
Easy to use Windows™ application, Most important functions and parameters directly available on main screen.Features: name/order/visibility of digital channels change, measurement cursors (voltage, time, frequency), reference signals, zoom, pattern search, signal prints, bus and state analysis feature, configuration save. |
| System requirements |
Pentium II or compatible, USB port, minimal screen resolution: 800 x 600 pixels (High Color). |
| Set contents |
ScopeLogicDAQ instrument, probes for digital signals (analog probe sold separately), power supplier, USB cable, CD with software |
 |